Innova Matrix™ Mk II+ E
The Innova Matrix™ MKII+E is a compact fiber optic multiplexer and control solution with a plug and play interface for a large array of sensors with a total of 7 Ethernet channels.
Description
The Matrix is a stand-alone fibre optic multiplexer and control solution. A plug and play interface for remotely operated systems, supporting a large array of sensors and equipment. The system consists of a compact, one-atmospheric subsea unit rated for 3000 MSW, and a 19” rack mounted topside unit with touch screen and status for all channels on the screen.
Check out other products of our Matrix family: Micro, Mini, Ocean, MKII+
Technical information
Topside:
- 7” Linux based touch screen interface for control and diagnostics
- Status for all channels on screen
- Voltage and current monitoring
- Alarm / warning logging
- Operational hours logged
- Web browser based interface for mirrored control
- Ethernet connection for control
- 19” 3U rack mount
- Wheight: 8 kg
Power input:
- Subsea: 85-264 VAC (47-63 Hz) / 120-370 VDC
- Topside: 90-265 VAC (47-63 Hz)
Power output:
- Software resettable fuses on DC power output
- 2 x 24 VDC / 48 VDC noise attenuated 6A – SW switchable
- 1 x 48 VDC (3A) / 24 (6A) fixed output – HW switchable
- 10 x 24 VDC (2A) outputs 2-pole relay
- 1 x 110 VAC 2-pole relay output (glass fused)
- 1050 W available DC power
Signal interface:
- 6 x RS232
- 3 x Software switchable RS232 / RS485
- 2 x 1 Gbps Ethernet
- 7 x 100 Mbps Ethernet
- 3 x HD-SDI
- 2 x 5 V TTL trigger
- All serial and trigger interfaces are isolated
- Optional: 3 x analog video instead of 3 x digital video
Mechanical properties:
- Aluminium 6082-T6, hard anodized or Titanium Gr. 5
- Dimensions: D 230 mm (223 mm), L 596 mm (Al) & L 584 mm (Ti)
- Weight Canister: 35 kg (air), 13 kg (sea)
- Depth rating: 3000 MSW (Al) & 5000 MSW (Ti)
- Shock and vibration: According to ISO 13628-6
Other:
- Two-stage noise attenuation filter on power input
- Humidity sensor subsea
- Temperature sensor topside and subsea
- DC ground fault detection system
- Fibre and SFP diagnostics
- Control board diagnostics
- Water ingress detection
Connectors:
- C1 5506-2021 1 Gbps Ethernet, RS232, 5 V TTL (PPS), Sync with C2, 24 / 48 VDC (6A), (SW switchable)
- C2 5506-2021 1 Gbps Ethernet, RS232, 5 V TTL (PPS), Sync with C1 24 / 48 VDC (6A), (SW switchable)
- C3 5506-2021 2 x 100 Mbps Ethernet, RS232 / RS485, (SW switchable), 5V TTL (PPS) 24 VDC (6A), Optional: 48 VDC (3A), (HW switchable)
- C4 455-L-FCR-75 Ω Camera 1 (HD-SDI), RS232 24 VDC (2A)
- C5 455-L-FCR-75 Ω Camera 2 (HD-SDI), RS232 24 VDC (2A)
- C6 455-L-FCR-75 Ω Camera 3 (HD-SDI), RS232 24 VDC (2A)
- C7 MCBH8F 100 Mbps Ethernet 24 VDC (2A)
- C8 MCBH8F 100 Mbps, Ethernet 24 VDC (2A)
- C9 MCBH8F 100 Mbps Ethernet, 5V TTL (PPS) 24 VDC (2A)
- C10 MCBH8F 100 Mbps Ethernet, 5V TTL (PPS) 24 VDC (2A)
- C11 MCBH8F 100 Mbps Ethernet 24 VDC (2A)
- C12 MCBH6F RS232 110 / 230 VAC (2A), (= input voltage)
- C13 MCBH8F RS232 / RS485, (SW switchable) 24 VDC (2A)
- C14 MCBH8F RS232 / RS485, (SW switchable) 24 VDC (2A)
- Fibre 472-G-BCR, SM, (OPT-G4-BCR,SM) Topside <-> Subsea, (Opt. Shilling fibre int.)
- Power G5506-2006 85-264 VAC (47-63 Hz) / 120-300 VDC